PDFPrintE-mail


Analog EMG Sensor to measure neural signal
View Full-Size Image


Analog EMG Sensor to measure neural signal

( DFR )
SG$57.00


INTRODUCTION

 

This EMG sensor can detect sEMG to reflect muscle and neural activities of human.

This sensor integrates filtering circuit and amplified circuit. It amplifies minimal sEMG within ±1.5mV 1000 times and depresses noises (especially power frequency interference) by differential input and analog filter circuit. The output signal is analog,which takes 1.5V as the reference voltage. The output voltage range is 0~3.0V. The signal strength depends on the intensity of muscle activities. The output signal waveform indicates the muscle activity and contributes to analyze and research the sEMG. Specifically, we can use Arduino as a controller to detect muscle activities, e.g. check whether the muscle is tense; the muscle strength, etc.

This is an active induction sensor can provide high quality signal collection and it is easy to use. Only simple preparations are needed to apply the module for either static or dynamic areas. Dry electrode is applied to the module and good quality signal are available even without conductive gel. Compared with disposable conductive gel needed by medical electrodes, it is more convenient to use and extend its long-life service. Therefore, it is more suitable for most of users. 

Measurements with an analog EMG sensor are noninvasive, convenient and this can be applied in human-computer interactions. With the development of microcontrollers and integrated electric circuits, EMG circuits and sensors have not been applied to traditional medical muscle detection researches but control systems.

Attention:
1. The supply voltage range is 3.3~5.5V; The supply current should not be less than 20mA; The ripple current and disturbance current should be as low as possible. Stabilized DC voltage is recommended.
2. The effective spectrum range is 20Hz~500Hz, and the ADC converter which has higher than 8-bit resolution and 1 kHz frequency are recommended to take samples and digitized to keep original information.
3. Placing the metal dry electrode should consistent with the direction of muscle.
4. The product is not a professional medical device and cannot diagnose and cure disease as an assistant device.

FEATURES

 

 

Metal Dry Electrode: long life, easy to use

Differential input, high common mode rejection ratio

Low power consumption

Single power supply

 

SPECIFICATION

 

Signal Transmitter Board

  • Supply Voltage: +3.3V~5.5V
  • Operating Voltage: +3.0V
  • Detection Range: +/-1.5mV
  • Electrode Connector: PJ-342
  • Module Connector: PH2.0-3P
  • Output Voltage: 0~3.0V
  • Operating Temperature: 0~50℃
  • Size: 22mm*35mm (0.87inch*1.38inch)

  • Dry Electrode Board

  • Electrode Connector: PJ-342
  • Wire Length: 50cm(19.69inch)
  • Plate Size: 22 * 35 mm (0.87*1.38inches)
  • weight: 36g
  •  

    DOCUMENTS

     

    Product wiki
    More Documents

     


    Availability

    In Stock: 1

    Usually ships in:

    2-3d.gif


    Customer Reviews:

    There are yet no reviews for this product.
    Please log in to write a review.




    Products Categories

    We Accept


     


    Shopping Cart

    Your Cart is currently empty.

    NOTE..


    -> NO GST -> NO GST -> NO GST

    Product Search



    Advanced Search

    Currency Selector




    HTTPS Secure